Category Top

Preventing Unauthorized Access

Increasing Security

Restricting Access by Authentication

Administrator Settings

Specifying the System Manager Settings

Department ID Management

Specifying Department ID Management

Checking/Printing/Clearing Page Totals

Accepting Jobs with Unknown Department IDs

Accepting B&W Print Jobs without Entering a Department ID

User Setting Information Management (User Setting Information Management Service)

Logging In to the User Setting Information Management Service Page

Deleting the User Setting Information

User Access Control for Advanced Box

Simple Authentication Settings for Secure Print

Setting to Disable Integrated Authentication

Network Security

Key Pair and Server Certificate Settings for Encrypted SSL Communication

Generating a Key Pair and Server Certificate

Registering a Key Pair File and Server Certificate File Installed from a Computer

Editing Key Pairs and Server Certificates

Registering/Editing a CA Certificate File

Verifying Certificate Validity Using Certificate Revocation List

Using an Encryption Method That Complies with FIPS 140-2

Network Settings/Management when Using an Advanced Box

MEAP Settings

Using the SSL

Printing Installed Application Information

Preventing Information Leakage

Forced Secure Watermark/Document Scan Lock

Secure Watermark (Forced Secure Watermark/Printer Driver Secure Watermark)

Adjusting the Secure Watermark Contrast

Document Scan Lock Settings

Specifying the Document Scan Lock Operational Settings
Setting the Document Scan Lock Mode
Adjusting the TL Code

Accepting Only Encrypted Secure Printing

Setting the Control Panel Display

Specifying Management Settings for the Memory

Completely Erasing Unnecessary Data from the Memory

Initializing All Data/Settings

TPM Settings

Device Management

Using the USB Port

Device Information Settings

Specifying Device Information Delivery Settings

Registering/Deleting/Printing Delivery Destinations

Setting the Receiving Machine

Setting Automatic Delivery

Setting Manual Delivery

Checking/Printing the Communication Log

Setting SSO-H Authentication for Device Information Delivery Settings

Limiting Functions

Remote UI

Clearing the Message Board

Saving a Log of Key Operations

ACCESS MANAGEMENT SYSTEM

Starting the Setup Guide

Retrieving Audit Logs

Available Administrator Settings Table (Touch Panel Display)

IEEE 2600 Security Standard

Top » Security » Specifying Management Settings for the Memory » Initializing All Data/Settings
Initializing All Data/Settings
0UKW-133
If this mode is performed, the following data stored in the machine are completely erased. It is not normally necessary to use this mode, but it is useful to erase personal or confidential information when returning or disposing of the machine.
[Favorite Settings] registered for the Access Files function
MEAP applications and license files
Data saved from MEAP applications
The password for the SMS (Service Management Service) login service of MEAP
(If you changed the password, it returns to the default password.)
User authentication information registered in the Local Device Authentication system of SSO-H (Single Sign-On H)
Job history
Settings/Registration settings
Key Pair and Server Certificate registered in [Certificate Settings] in [Device Management] in [Management Settings] (Settings/Registration)
IMPORTANT
Before initiating the Initialize All Data/Settings mode, make sure that the data you are erasing is completely unnecessary. Note that Canon will not be liable for any damages resulting from the loss of data.
To prevent other users from accidentally erasing all the data in the memory, it is recommended to register a System Manager ID and System Manager PIN so that only the System Manager can perform this procedure.
Confirm that there are no current jobs being processed before using the Initialize All Data/Settings mode.
Backup or export any necessary data before erasing the data in the machine. You can backup or export the following data:
Data you can export using the Remote UI
(Depending on the MEAP application, you may be able to backup this data. For more information, see the manual for the MEAP application you are using.)
License files for MEAP applications
(For information on downloading license files, see "Managing Application Licenses.")
User authentication information registered in the Local Device Authentication system of SSO-H (Single Sign-On H)
(For information on exporting authentication information, see "Registering/Editing User Data for Local Device Authentication.")
Settings which can be sent using the Device Information Delivery mode
(Can only be backed up if you have another printer with the Device Information Delivery mode. It is not necessary to back up this data if you want to use the data already registered in the other printer.) For more information on the Device Information Delivery mode, see "Specifying Device Information Delivery Settings.")
Data saved from MEAP applications
(Depending on the MEAP application, you may be able to back up this data. For more information, see the manual for the MEAP application you are using.)
After initializing data, the Initialize All Data/Settings Report is automatically printed to confirm initialization. Use the report to check the following items.
Serial Number
The serial number of the machine is printed.
Device Name
The device name of the machine is printed.
Overwrite Method for Deletion Mode
The deleted contents and deletion mode are printed.
NOTE
The Initialize All Data/Settings Report is printed in English only.
Although the job logs are deleted when the Initialize All Data/Setting mode is performed, the log which shows the Initialize All Data/Settings Report has been printed appears in [Log].

1.
Press (Settings/Registration).
2.
Press [Management Settings] → [Data Management] → [Initialize All Data/Settings].
3.
Select the deletion mode → press [Start].
Details of each item are shown below:
[Once with 0 (Null) Data]:
Overwrite the data once with 0 (null) data.
[Once with Random Data]:
Overwrite the data once with random data.
[3 Times with Random Data]:
Overwrite the data three times with random data.
[9 Times with Random Data]:
Overwrite the data nine times with random data.
[DoD Standard]:
Overwrite the data three times. The first time is with a fixed value, the second time with a complement of the fixed value, and the third time is with random data.
It may take more than 30 minutes to initialize the memory.
By executing the Initialize All Data/Settings mode, the machine will automatically restart.
After the machine restarts, Initialize All Data/Settings Report will be printed automatically.
IMPORTANT
If there are any current jobs being processed, they will be canceled, and then erased.

IMPORTANT
You cannot access the machine while the memory is being initialized.
NOTE
For information on Initialize All Data/Settings Report, see "Initialize All Data/Settings Report."